HaptiData

Every byte of the tactile stream, written down.

The sensing fabric is hard to make. Reading it should not be. Frames arrive on an open serial port at 921,600 bps: four magic bytes, a packet counter, a sensor byte, 256 eight-bit cells and a quaternion. No SDK, no licence check, no gated API, this page is the entire format, plus the cell map, so your ROS or Python stack can consume the skin without going through us.

256cells per frame
162used per glove
0bytes encrypted

Last reconciled with the manufacturer specification on 2026-11-20.

1, Frame anatomy

A frame is fixed-length once you know the packet number. Two packets carry one 256-cell update; the second packet also carries the IMU.

FieldBytesValueMeaning
Header4AA 55 03 99Frame start, fixed. Nothing else begins with these bytes.
Packet101 / 0201 = cells 1 to 128, 02 = cells 129 to 256 plus IMU.
Sensor101…0501 LH, 02 RH, 03 LF, 04 RF, 05 WB.
Cells12800…FFRaw 8-bit pressure. 0 = no load. Not yet in newtons: see calibration below.
Quaternion164 × int16 LEPacket 02 only. q0 to q3, little-endian signed.

So packet 01 is 134 bytes and packet 02 is 150 bytes, header included. A decoder only needs a sliding window: look for AA 55 03 99, read the packet byte, then read 129 or 145 more bytes.

What a frame looks like

AA 55 03 99 | 01 | 02 | 00 00 07 1C 2B 33 21 0F 00 00 ...
^ header     ^pkt ^RH  ^ cell 1, cell 2, cell 3, … (128 bytes)

second packet, same update:
AA 55 03 99 | 02 | 02 | 00 00 06 19 28 30 22 10 00 00 ...
                        ^ cells 129…256 (128 bytes)
                        ^ then 16 bytes: q0 q1 q2 q3 as int16 LE

Calibration, stated plainly

The cell byte is a raw ADC value, 0 to 255. The specification characterises the sheet as a whole (350 N peak per point, 0.01 N resolution, ±8 % repeatability and ±8 % part-to-part consistency), not per cell. If you need newtons per cell, fit a two-point curve per sensor on your own rig: load a known mass, record the byte, repeat at a second mass, then interpolate. We publish the raw value deliberately, a factory-supplied per-cell Newton table would be a guess dressed up as data.

2, Cell map, both hands

Indices are 1-based as printed in the specification. Byte position in the stream is index − 1. A glove fills 162 of the 256 cells; the rest are padding and read as zero.

Left hand, pressure cells per finger

FingerCell indices (12 per finger)
Little31, 30, 29, 15, 14, 13, 255, 254, 253, 239, 238, 237
Ring28, 27, 26, 12, 11, 10, 252, 251, 250, 236, 235, 234
Middle25, 24, 23, 9, 8, 7, 249, 248, 247, 233, 232, 231
Index22, 21, 20, 6, 5, 4, 246, 245, 244, 230, 229, 228
Thumb19, 18, 17, 3, 2, 1, 243, 242, 241, 227, 226, 225

Left bend channels: little 222, ring 219, middle 216, index 213, thumb 210. Palm: 207, 206, 205, 204, 203, 202, 201, 200 … 132, 131, 130, 129 (72 cells).

Right hand, pressure cells per finger

FingerCell indices (12 per finger)
Thumb240, 239, 238, 256, 255, 254, 16, 15, 14, 32, 31, 30
Index237, 236, 235, 253, 252, 251, 13, 12, 11, 29, 28, 27
Middle234, 233, 232, 250, 249, 248, 10, 9, 8, 26, 25, 24
Ring231, 230, 229, 247, 246, 245, 7, 6, 5, 23, 22, 21
Little228, 227, 226, 244, 243, 242, 4, 3, 2, 20, 19, 18

Right bend channels: thumb 47, index 44, middle 41, ring 38, little 35. Palm: 61, 60, 59, 58, 57, 56, 55, 54 … 117, 116, 115, 114 (72 cells).

The bend channel is not a pressure cell: it is a separate resistive element that reports knuckle angle, which is why the two hands use completely different indices for the same finger. Treat it as its own axis.

tactile-map.json, the same tables as machine-readable JSON, including the full palm arrays.

3, What the sheet will take

PropertyValueNote
Thickness≤ 2.33 mmIncluding the fabric cover
Peak load, per point350 NMean maximum range
Resolution0.01 NIdentification, not full-scale accuracy
Repeatability / consistency± 8 % / ± 8 %Same point / between parts
Endurance200,000 cycles at 3 MPaAutomotive-grade Z-fold test, self-recovering
IngressIP21Dry cloth cleaning only
Operating temperature−20 … 60 °CStorage −40 … 80 °C
Humidity< 90 % RHNon-condensing; storage ≤ 93 % RH
Supply5.0 V / 2 AOr 3.7 V / 300 mAh battery; 3.5 to 5.0 V working range
Current48 mABluetooth runtime 3.75 h, standby one week
Sample rate100 Hz100 Hz wired, customisable to ≤ 600 Hz
Latency< 0.2 msSensor response, before transport
Link921,600 bpsUSB serial or Bluetooth receiver

Parts and their weights

PartSizeWeight
Batterynot applicable14.8 g
Bluetooth receivernot applicable13.2 g
ESP32 controller boardnot applicable6.6 g
USB expandernot applicable45 g
Data cable2 m, USB 3.0 → type-C67.3 g
Controller housing50 × 32 × 15.5 mm10 g
Carton30 × 20 × 15 cm166 g

IMU

TDK InvenSense ICM-42688. Gyro ±15.625 … ±2000 °/s, accelerometer ±2 … ±16 g, both 16-bit, bundled into the quaternion above. It is a separate chip on the controller board, not part of the fabric.

4, Running it without guesswork

Indicator codes

ColourStateMeaning
Blue steadyLinked, high cellBattery > 3.3 V
Green steadyLinked, mid cell3.1 < V ≤ 3.3
Red steadyLinked, low cell≤ 3.1 V
Red blinkingNot linked< 3 V, or pairing lost
Blue blinkingNot linkedAdvertising, awaiting AT+CONN
White steadyChargingCharge LED on the board

One minute without a pressure change puts the board to standby and the LEDs go dark; press the button to wake it. Short press while asleep activates the device, a short press while awake re-runs the ICM-42688 calibration, and a long press until the red LED fades powers it down.

Pairing a receiver by hand

port       COMx            any serial terminal at 921,600 bps
options    no "HEX display", append CR+LF

AT+SCAN=1                  lists nearby devices; find the line JQ-RH_…
                           (JQ-LH left hand, JQ-RH right hand, JQ-LF / JQ-RF
                           feet, JQ-WB body, JQ-FB chest)
AT+CONN=<address>          connect with the 12-hex-digit address printed
                           in front of the device name

If pairing fails, unplug and replug the receiver, confirm the glove is in blue-blink state, then repeat. The address in the manufacturer’s worked example carries a trailing extra digit, use exactly the twelve hex characters that precede the JQ-xx_? name, nothing else.

Handling

Dry cloth only, no solvents. Keep sharp edges off the sensor, do not pull the lead, do not open the housing, and stop using it if the surface is torn, the sheet is a precision element, not a consumable.

5, Software, and what it is for

The desktop application is a viewer and recorder. It is not an access gate: the same bytes it draws are the bytes your own code reads.

FunctionDetail
Live pressure view3D surface, 2D heat map, raw 16 × 16 matrix
Record and replaySession capture with playback
ExportCSV of the raw cell values
Multi-sensorSeveral sensors on screen at once, multiple viewpoints
Interface languageChinese and English
PlatformsWindows 8 or newer, macOS
LicencePer workstation, per year; the check runs online, so a VPN on the machine blocks startup

Where the viewer is not enough, recording inside a ROS node, aligning frames with a camera, batch-labelling, write your own. protocol.py is a complete decoder in one file.

6, Take the files

python3 protocol.py capture.bin
python3 protocol.py --hex frames.txt

sensor RH, 284 bytes, 2 frames
  0   0   7  28  43  51  33  15   0   0 …
quaternion (raw int16): (0, 0, -16384, 0)

Provenance and maintenance

Every number on this page comes from the manufacturer’s specification for the fabric glove (HaptiData, document revision V1.1). The document’s cover sheet still reads V1.0 dated 2025-12-18 while the file is named V1.1 dated 2026-03-23; where they disagree we follow the later body and will reconcile the moment the manufacturer reissues. Both documents are now mirrored with the manufacturer’s agreement: the specification PDF sits on the documents page byte for byte with its checksum, and the viewer installers are handed out with a licence seat.

A scheduled job on our side watches the manufacturer’s site and this page for changes, so a revision does not sit unnoticed. If you build against this format and something stops parsing, send us the capture: the header, the packet byte and the sensor byte are enough to tell whether the revision moved.

Sensing hardware, supply, fit adaptation and integration: HaptiData.